108 Series Exposed Frame Double Glazed with Blinds
(1).jpg?x-oss-process=image/resize,w_900,m_lfit)
(1).jpg?x-oss-process=image/resize,w_900,m_lfit)
.jpg?x-oss-process=image/resize,w_900,m_lfit)
.jpg?x-oss-process=image/resize,w_900,m_lfit)
.jpg?x-oss-process=image/resize,w_900,m_lfit)
.jpg?x-oss-process=image/resize,w_900,m_lfit)
Details
1. The frame is constructed with an internal steel and external aluminum structure. It features suspended, removable panels with independent, detachable components. Once removed, the overall frame integrity and safety remain unaffected.
2. All finished partition profiles: standard sections have a wall thickness ≥1.2mm, while load-bearing sections are ≥2.0mm.
3. The partition studs are galvanized steel columns. They utilize 1.2mm thick high-strength galvanized steel sheet, integrally formed and bent into an H-shaped longitudinal support.
4. Double-sided 6mm tempered clear glass is standard. Optional 25mm wide, 0.18mm thick aluminum venetian blinds with hardware are available (blinds selected as needed).
5. Standard aluminum frame colors: sand-textured black, matte white, custom grey.
6. The complete partition system has a finished thickness of 108mm; panels are full-height, floor-to-ceiling.
7. Overall acoustic performance: sound insulation ≥46 dB, complying with standard GB/T 19889.3-2005 (Laboratory measurement of airborne sound insulation of building elements).
8. Strength and stability comply with GB/9926-1999: maximum dynamic load of 315 N/m, maximum static load of 2.5 kN/m.
9. The finished glass partitions can be integrated with service channels (power/data) and doors, forming a complete system.
Attention
1. Do not use sharp objects to directly cut, scratch, or strike the glass partition surface to avoid scratches, cracks, or holes. Avoid heavy impacts that could damage the glass partition.
2. For routine cleaning, wipe aluminum-framed glass partitions with a soft cloth moistened with clean water or a neutral detergent. Do not use hard scrubbing tools on metal-painted surfaces. Avoid abrasive or corrosive cleaners, as they may damage the metal-coated surface.
3. Glass partitions are non-load-bearing walls; avoid hanging heavy objects on them.