90cm Wall-Mounted Chinese Range Hood


Details
• Range Hood Type: Wall-mounted T-shape
• Width (cm): 90
• Control Type: Push-button control
• Max Airflow (m³/h): 1200
• Noise Level dB(A): 55
• Energy Efficiency Grade: A (or Level 1)
• 2 LED Light Strips
• Lighting Power: 2 x 6.5W
• Stainless Steel Grease Filter Grilles: 2 pcs
• Polished Interior for Easy Cleaning
• Installation Type: Ducted (Venting outside)
Attention
1. The appliance comes with a power cord fitted with a Chinese standard plug; a compatible local socket (e.g., Type G for UK/Ireland, Type B for North America) must be provided by the customer. The power cord exits near the air outlet and is 1 m long. The power supply point should be located 100 mm above the ceiling, directly above the cooker hood. The electrical supply and wiring must comply with local regulations and match the hood's power requirements (10 A).
2. Before installing the cooker hood, the customer must pre-install a non-return damper on the communal duct and the exhaust duct (duct diameter: use a 200 mm internal diameter pipe). A 300 mm × 400 mm access hatch must be left in the ceiling below the non-return damper for future maintenance. The connection between the exhaust duct and the damper must be tight and secure. The non-return damper and exhaust duct are not included with the hood and must be purchased separately by the customer.
3. The hood's air outlet diameter is 200 mm. A 250 mm diameter hole must be cut through the ceiling directly above the hood and flush against the wall, allowing the exhaust duct to pass through (leave approximately 100 mm of duct protruding below the ceiling).
4. The exhaust duct must be flexible aluminium foil or rigid fire‑rated duct. The duct length must not exceed 2 m. The run from the non‑return damper to the hood should be as short and straight as possible (a 90° elbow or 1 m of flexible duct reduces extraction efficiency by at least 15%). If the duct needs to bend inside the ceiling or exceeds 2 m, the customer must revise the design and reposition the hood.
5. The distance between the hood's air outlet and the ceiling must be ≥300 mm to prevent a 90° bend directly at the outlet (a sharp bend obstructs airflow, increases noise, reduces extraction and intake performance, and traps heat at the bend, shortening the hood's service life).
6. The wall on which the hood is mounted must be solid and capable of bearing a weight of 60 kg. A qualified electrician must identify the location of concealed cables, pipes or other services inside the wall before drilling, to avoid electric shock and damage to hidden infrastructure.
7. The appliance must not be installed in a location with strong air drafts, as this may impair extraction performance.
8. Recommended installation height: when used with a gas hob – 700 mm between the bottom of the hood and the hob; with an induction hob – 600 mm between the bottom of the hood and the hob.
9. If the customer needs to extend the stainless‑steel chimney cover, a custom extension must be ordered separately.