GATSBY Water Vapor Fireplace Insert


Details
GATSBY Built‑in Water Vapor Fireplace Insert
Art‑Deco style electric water vapor fireplace, recessed installation
Gatsby revives the decorative water vapor fireplace. Its Art‑Deco design creates a chic, elegant ambiance. The geometric insert is a result of advances in electric water vapor fireplace technology. It integrates effortlessly into any chimney breast or mantel, or can stand alone as a decorative flame feature, complementing any interior style.
Gatsby is an eco‑friendly, built‑in cool‑flame water vapor fireplace insert, delivering absolute safety and producing no harmful emissions – only pure water ions. This insert is ideal for families with children, as well as safety‑conscious public spaces and hospitality environments.
Breathe new life into your existing fireplace setting with the Gatsby water vapor insert. It offers an environmentally responsible, totally safe fireplace solution with authentic flame realism. Press a button on the remote control to instantly create a lively, warm atmosphere – without the mess of wood or fuel.
Gatsby comes with 2 black spheres and 2 gold spheres for the on/off control.
The GATSBY eco‑friendly built‑in water vapor fireplace insert is an innovative solution that provides a cozy atmosphere while embracing green principles. By using ultra‑fine water ions, this remote‑controlled insert reproduces the look of real flames without any exhaust fumes, soot or pollutants. It is an eco‑conscious alternative to traditional fossil‑fuel and wood‑burning fireplaces, and an ideal way to combine home comfort with a reduced carbon footprint.
Moreover, this built‑in cool‑flame water vapor fireplace ensures 100% safety, eliminating any risk of burns or fire hazards. It offers complete peace of mind for you and your family. The GATSBY smokeless water ion fireplace is not only harmless to health – the negative oxygen ions released can even benefit human well‑being.
GATSBY Built‑in Water Vapor Fireplace – Dimensions & Technical Specifications
GATSBY Technical Specifications
Matt black (RAL 9005) insert
Supplied with 2 black spheres and 2 gold spheres
Remote control & onboard buttons – flame height adjustment, flame speed adjustment, LED intensity adjustment
UVC air & water disinfection – integrated pump for automatic filling (no water supply connection required) – manual drainage (no water supply connection required)
External control via dry contact
Natural orange flame
The GATSBY remote‑controlled water ion fireplace generates no surrounding humidity or condensation. The ultra‑fine water ions are instantly absorbed by the ambient air, leaving no water droplets on walls.

Attention
Use and Maintenance Precautions
The AFIRE ionizing water vapor fireplace is equipped with LED lights. To avoid glare, do not look directly down at the light source from above the fireplace.
The AFIRE water vapor fireplace contains an ultrasonic atomizer (the atomizer is a consumable item). Operation is very simple (see video). Note: Consumable items are not covered by warranty. Both the ultrasonic atomizer and the remote control fall into the category of consumables.
Note: If the unit will not be used for more than a week, please drain the water to prevent leakage. The drained water does not need to be connected to a wastewater system.
Atomizer Cleaning Steps:
• Turn off the fireplace, disconnect each atomizer connector plug from the fireplace, and remove the atomizer and bracket.
• Depending on the severity of limescale, apply a few drops of white vinegar directly onto the atomizer, let it sit for a few minutes, then scrub the atomizer and bracket clean with tap water.
• If there is residue such as limescale in the gap between the bottom of the atomizer and the bracket, unscrew the 4 screws securing the atomizer and clean its underside. Remember: avoid letting the atomizer's wiring come into contact with the vinegar solution.
• During cleaning, you may use a soft-bristled toothbrush or a soft cloth to gently scrub any visible stains on the white surface, metal housing, and bottom of the atomizer. Do not use hard-bristled brushes, scouring pads, or other harsh cleaning tools, as these may cause permanent damage to the atomizer.
• Reassemble the atomizer onto the bracket, then place the atomizer bracket back into the mist chamber.
• Before tightening the atomizer cover, ensure that the atomizer wiring is placed inside the groove on the side of the mist chamber. Reconnect the atomizer wiring plug to the fireplace, and the atomizer cleaning is complete.
Fireplace Cleaning Steps:
• If your fireplace is directly connected to the tap water supply, turn off the water supply valve.
• For AWPR2 series models, connect the inlet/drain hose to the port next to the fireplace's control button. (For AWAL or AWA2 series models, use a manual drain pump and place it into the water tank and mist chamber respectively to drain manually.)
• Place the outlet end of the inlet/drain hose into a bucket, then press and hold the left button (B2) for 5 seconds to start draining. When draining stops, some water will remain in the mist chamber; this is normal. You can use a smaller siphon hose, a large glass dropper, or a clean cotton cloth to absorb the small amount of remaining water inside the mist chamber. Try to avoid placing any material that may shed debris into the mist chamber.
• After the fireplace is drained, add a mixture of water and white vinegar in a 4:1 ratio into the fireplace. Alternatively, pour the 4:1 water-vinegar solution directly into the mist chamber, being careful not to overfill, as this may cause overflow. When the solution level is just above the top of the atomizer itself (approximately 5.5–6 cm from the bottom of the mist chamber, with a water capacity of about 1000 ml per mist chamber), the fireplace will have enough vinegar solution. Caution: overfilling may cause excess vinegar solution to leak from the front fan.
• As with the atomizer soaking operation described above, allow the vinegar solution to sit in the tank for about 10–20 minutes, letting it react with any limescale deposits on the float sensor, making them easier to remove.
• Do not operate the fireplace during the vinegar solution cleaning process.
• After the soaking period (before draining), quickly shake the atomizer bracket up and down to agitate the vinegar solution in each mist chamber, helping to dislodge limescale residues from the float sensor. At this point, you can hear the float sensor moving inside the lower tank; repeat this action 10–15 times for each mist tube.
• Drain the vinegar solution from the fireplace in the same way as normal draining. Press and hold the left button (B2) for 5 seconds to start draining (AWAL and AWA2 series require a manual drain pump). When draining stops, some water will remain in the mist chamber; this is normal. You can use a smaller siphon hose, a large glass dropper, or a clean cotton cloth to absorb the small amount of remaining water. Try to avoid placing any material that may shed debris into the mist chamber.
• After the vinegar solution is drained, fill the fireplace tank with water. If it is connected directly to the tap water supply, reopen the water supply valve and the system will automatically refill upon startup. You can also use the inlet/drain hose and press and hold the fill button (B1) to add water.
• You need to perform two complete fill-and-drain cycles on the entire unit to ensure the removal of vinegar solution and all suspended limescale and dust residues. After filling the system for the third time, the fireplace can be used as usual.
• Wipe the fireplace surface with a damp cloth to remove any dust or limescale marks.
Cleaning the atomizers 2–3 times a year and performing a full system clean 1–2 times a year will help extend the life of the atomizers, float sensor, and the fireplace itself. However, irregular use or hard water areas may require more frequent cleaning. If you have any questions, please feel free to contact your local dealer or us for assistance. Once you try these cleaning steps yourself, you will find that maintaining your fireplace is very simple and effortless.