Master Key Cylinder



Details
1. The supplier shall provide a set of temporary cylinders and temporary keys for use during the construction period; the quantity depends on site usage.
2. The final master key cylinders shall be handed over and signed off by the owner, the fit-out contractor, and the door hardware/cylinder supplier jointly after construction is completed.
3. The supplier must be capable of producing a master key system of Level 6 or higher (exact hierarchy to be refined according to the hotel operator's requirements) with a master key system capacity of no less than 3,000 individual cylinders (excluding KA alike cylinders), allowing the owner or user to expand the system in the future.
4. The supplier must be able to integrate European profile cylinders, glass door floor lock cylinders, panic exit device outside cylinders, and other cylinder types into a unified master key management system.
5. The keyway profile must be proprietary to the supplier’s factory and not freely available on the open market, preventing unauthorized key duplication.
6. European profile cylinders must be certified to EN 1303; corresponding test reports shall be provided.
7. ANSI/BHMA cylinder must be tested to ANSI 156.5 and provide corresponding test reports. Floor locks must be equipped with 6-pin interchangeable cores to facilitate future master key cylinder replacement without the need to remove the door leaf.
8. Based on the owner’s system structure, assist in preparing the master key system scheme and door schedule. Keys and cylinders must have corresponding numbers for proper installation and key management. Each cylinder comes with 3 individual keys. All management keys shall be provided in quantities of 5 each.
9. Cylinder lengths must suit on-site door leaf requirements. Finishes shall be custom as specified.