1/2
Find
WPC Herringbone Flooring
Reference Price:USD/㎡
Brand:NAVIGATEC
Material No.:YMONE4Z1
Supplier: CONTACT US
Material ID:
Add to Project
Material Consultation
Overview
Product Reports
Documents
Specifications
Product Model:ZY80502
Country of Origin:Jiangsu Province, China
Abrasion Resistance Class:T-class
Size(mm):498*83
Color:Black Series
Content:Vinyl flooring
Surface Treatment:Wear-resistant Layer + UV
Flammability:B1
Wear Layer Thickness(mm):0.5mm
Slip Resistance:R11
Indoor & Outdoor:Indoor
Overall Thickness(mm):8
Brand Name:NAVIGATEC
Series Name:Herringbone Wood
Category:Flooring/PVC Flooring
Customizable:Yes
Material Spelling
Overview
Case Diagram





Details
Underfloor Heating Installation and Usage Requirements
① During the first three days after turning on the heating system, allow the flooring to gradually warm up by maintaining a surface temperature 3°C–4°C higher than the room temperature. In normal operation, the water pipe temperature should be 50°C–60°C, the floor surface temperature must not exceed 27°C, and the room temperature should ideally remain between 18°C and 25°C.
② In underfloor heating environments, do not cover the floor surface with rugs or carpets for extended periods, as this can cause localized overheating and lead to floor cracking.
③ It is recommended to keep indoor relative humidity between 45% and 75%. Prolonged humidity below 40% can cause gaps between planks; consider using a humidifier or placing indoor plants to increase moisture levels.
Attention
ZhengHang SPC/WPC Standard Installation and Usage Guide
International SPC (Stone Plastic Composite) flooring installation standards commonly refer to ISO 14025:2005 "Resilient floor coverings — Installation guidelines" and national standards such as European EN 13329 and American ASTM F2179. These standards specify installation procedures, performance requirements, and testing methods to ensure stability and durability. Below are key points of the international SPC flooring installation standard:
1. Subfloor Preparation
- Flatness: The subfloor must be flat; unevenness should not exceed 3 mm over a 2 m length.
- Dryness: The subfloor must be dry, with moisture content not exceeding 8% of the local equilibrium moisture content. Use a moisture meter for measurement.
- Cleanliness: The subfloor must be clean, free of oil, dust, and other debris.
- Moisture Protection: In damp areas such as basements, moisture protection is required, e.g., laying a moisture barrier film. The film should be at least 0.2 mm thick, with overlaps of no less than 100 mm.
2. Installation Methods
- Floating Installation: SPC flooring is typically installed as a floating floor, i.e., not directly fixed to the subfloor but connected via a click-lock system. Start from the innermost corner of the room and lay lengthwise.
- Glue-Down Installation for Hydronic Heating: In cases such as underfloor heating systems or when extra stability is required, use adhesive to bond SPC/WPC flooring to the subfloor. Choose adhesive recommended by the manufacturer and follow application instructions.
3. Expansion Gaps
- Perimeter Expansion Gap: Leave an 8–10 mm expansion gap around the perimeter to accommodate expansion and contraction due to temperature and humidity changes.
- Expansion Gaps around Obstacles: Leave appropriate expansion gaps around obstacles (walls, columns, pipes, etc.).
4. Joint Technique
- Secure Joints: Ensure planks are firmly connected with even gaps at seams. Use specialized tools for joining; avoid excessive force to prevent damage.
- Joint Sequence: Start from the innermost part of the room and lay lengthwise, making sure each plank is securely locked.
5. Environmental Requirements
- Temperature: The installation environment temperature should be maintained at 18–25°C.
- Humidity: Relative humidity should be between 45% and 65%.
- Installation Area: Maximum continuous length/width without a break is 6 m; for runs longer than 6 m, an expansion joint of at least 10 mm must be provided.
6. Maintenance and Cleaning
- Daily Cleaning: Use a soft cloth or microfiber mop for routine cleaning. Avoid chemical cleaners that may damage the floor surface.
7. Special Considerations
- Underfloor Heating Systems: If an underfloor heating system is present, select SPC/WPC flooring rated for such use and follow the manufacturer's special installation guidelines. Ensure the heating system surface temperature does not exceed 28°C.
- Special Note: Electric underfloor heating systems (dry systems) are not suitable for SPC/WPC flooring.
- Additional Moisture Protection: In environments with high humidity and large temperature differences, extra moisture protection measures, such as a moisture barrier film, may be required.
8. Safety Precautions
- Safety Equipment: Ensure adequate ventilation during installation to avoid inhaling dust generated from cutting. Use safety equipment such as gloves and goggles to prevent injury.
9. Quality Assurance
- Quality Inspection: After installation, perform a comprehensive quality check to confirm all steps meet the standards.
- Warranty Service: If problems occur, contact the manufacturer or installation team promptly for repairs and warranty service.