Safety Anti-Pinch Device


Details

Attention
Automatic sliding doors are powered systems. To ensure pedestrian safety, safety light curtains (photoelectric sensors) must be installed during use. In practice, safety light curtains are supplementary equipment; many automatic sliding door users fail to install them, leading to numerous entrapment incidents. Although automatic sliding doors typically include pinch-proof sensors, they still have blind spots, which safety light curtains effectively cover.
Installation location: Typically, the safety light curtain is mounted on the outer side of the fixed door leaf columns on both sides (usually with the active door leaf hanging located on the inner side).
When installing the light curtain heads, drill a 13 mm diameter hole. For a single-beam system, the recommended installation height is 60 cm above the floor. For a dual-beam system, drill two 13 mm diameter holes: one set at 30 cm and another at 90 cm above the floor.
Although safety light curtains have excellent resistance to natural light interference, avoid directing intense sunlight straight into the light curtain heads during installation.
The through-beam transmitter and receiver have a certain automatic alignment tolerance, but they must be aligned properly during installation to ensure horizontal and vertical consistency.
Do not place potted plants or other obstructions between the through-beam transmitter and receiver, as this may cause false triggering.